Signup our newsletter to get update information, news, insight or promotions.

Latest Post & Article

Latest Post & Article

Page: Blog

Residential

26 Jun 2025

This article covers advanced methods, materials, and considerations for installing insulation over metal deck roofs in modern construction.

Disclosure: As an Amazon Associate, EnvelopeIQ earns from qualifying purchases.

Expanded Guidance

This article on Installing Insulation Over Metal Deck Roofs includes key strategies for envelope continuity, product selection, code compliance, and typical failures to avoid. Systems are described with links to example products and performance tips based on field conditions.

🔍 Recommended Products

Best Practice Tips

  • Ensure compatibility with adjacent layers and substrates
  • Sequence flashing and weather barriers shingle-style
  • Use mockups and field adhesion tests before bulk installation
  • Coordinate across trades to maintain control layer continuity

Fire Resistance and Attachment

Over-deck insulation systems must meet fire ratings (Class A) when exposed to flame spread. Use mechanically attached or adhered systems depending on structural requirements. Stagger joints between insulation layers and integrate with vapor and air barriers below.

Insulation Strategy Over Steel Decking

Metal deck roofs require thermal insulation layers that prevent condensation, resist compression, and meet R-value targets. Install cover boards over polyiso to resist foot traffic and membrane adhesion. Use mechanical fasteners or low-rise foam adhesives depending on wind uplift design pressures.

Common System Layers

  • Steel deck substrate
  • Vapor barrier (if required by climate)
  • Polyiso or mineral wool insulation in 2+ layers
  • Cover board (gypsum or high-density foam)
  • Single-ply membrane or BUR/MB roofing

Recommended Products

Vapor Barrier Considerations

In colder climates or buildings with high interior humidity (such as natatoriums or food production), a vapor barrier is typically installed over the steel deck before insulation layers. This prevents warm moist air from condensing within the insulation assembly. Select self-adhered vapor retarders compatible with polyiso or mineral wool and tested for peel adhesion on metal substrates.

Wind Uplift and Fastener Patterns

Use FM Global or ANSI/SPRI guidelines to determine insulation fastener spacing and pattern for each roof zone—corner, perimeter, and field. Multiple layers of insulation should be staggered with joints offset to avoid thermal bridging. Roof boards must resist uplift pressures and protect membrane adhesion. Use insulation adhesives or induction-welded fasteners for low-slope membrane roofs where mechanical fasteners risk thermal bridging.

Coordination with Other Trades

Before insulation is installed, coordinate with MEP and structural teams to route any penetrations, curbs, or drains. Improper sequencing can lead to unnecessary penetrations in air or vapor barriers. Ensure fire-rated assemblies at rated walls or access paths and verify tapered insulation slopes match drainage intent.

Inspection and Maintenance

After installation, inspect insulation for moisture intrusion or crushing from staging materials. Damaged insulation reduces thermal performance and can degrade membrane adhesion. Schedule routine inspections at rooftop equipment, perimeter edges, and exposed fastener zones for signs of uplift, ponding, or displacement over time.

Residential

26 Jun 2025

This article covers advanced methods, materials, and considerations for parapet detailing for thermal, air, and moisture control in modern construction.

Disclosure: As an Amazon Associate, EnvelopeIQ earns from qualifying purchases.

Expanded Guidance

This article on Parapet Detailing for Thermal, Air, and Moisture Control includes key strategies for envelope continuity, product selection, code compliance, and typical failures to avoid. Systems are described with links to example products and performance tips based on field conditions.

🔍 Recommended Products

Best Practice Tips

  • Ensure compatibility with adjacent layers and substrates
  • Sequence flashing and weather barriers shingle-style
  • Use mockups and field adhesion tests before bulk installation
  • Coordinate across trades to maintain control layer continuity

Parapet Cap Flashing Integration

Parapets must include metal coping or cap flashing secured to blocking, lapped over base flashing. Extend membrane up and over the parapet wall, and install closure strips or sealant at fasteners. Incorporate thermal breaks to prevent heat loss at the parapet slab interface and include through-wall scuppers where required.

Thermal Bridging at Parapets

Parapets often interrupt the continuity of roof insulation, becoming major thermal bridges. To mitigate this, extend insulation over the parapet or install continuous rigid insulation on the exterior parapet face and top. Use thermal break materials beneath parapet blocking or coping channels to limit conductive heat flow.

Air Barrier Continuity

Extend the roof air barrier vertically up the back side of the parapet and over the top edge. Tie the air barrier into the wall air barrier below using compatible materials and sealants. Mechanical fasteners that penetrate the air barrier should be sealed with gaskets, tape, or membrane patches.

Moisture Management Strategies

Properly sloped parapet caps and flashing are critical to prevent ponding water. Flashing should project at least Âľ” beyond the wall face and include drip edges. Parapets taller than 24″ may benefit from base-of-wall through-wall flashing to intercept driven rain and condensation.

Fire and Wind Resistance

Many jurisdictions require parapets to act as fire barriers. Use non-combustible materials and install fire-blocking insulation such as mineral wool at the parapet cavity. Secure coping against uplift forces with mechanical clips tested for wind resistance per ANSI/SPRI ES-1.

Integrated Coping and Cap Flashing

Use pre-formed metal coping systems with internal splice plates and foam closure gaskets. Stainless steel or Kynar-finished aluminum offers high durability. Ensure minimum 6″ overlap at joints and use compatible fasteners to avoid corrosion. Inspect for sealant failure and uplift gaps during annual maintenance.

Residential

26 Jun 2025

This article covers advanced methods, materials, and considerations for liquid-applied vs sheet membranes in below-grade waterproofing in modern construction.

Disclosure: As an Amazon Associate, EnvelopeIQ earns from qualifying purchases.

Expanded Guidance

This article on Liquid-Applied vs Sheet Membranes in Below-Grade Waterproofing includes key strategies for envelope continuity, product selection, code compliance, and typical failures to avoid. Systems are described with links to example products and performance tips based on field conditions.

🔍 Recommended Products

Best Practice Tips

  • Ensure compatibility with adjacent layers and substrates
  • Sequence flashing and weather barriers shingle-style
  • Use mockups and field adhesion tests before bulk installation
  • Coordinate across trades to maintain control layer continuity

Adhesion and Sequencing Considerations

Sheet membranes require consistent substrates and primer application. Liquid-applied products adapt better to irregular substrates but may require longer cure times. Test adhesion in wet or dusty conditions. Sequencing is critical: always extend the membrane past footings and tie into vertical barriers at grade transitions.

System Selection: Liquid vs Sheet Membranes

Below-grade waterproofing relies on two dominant systems: fluid-applied membranes and sheet-applied membranes. The choice depends on jobsite conditions, substrate irregularity, hydrostatic pressure, and project schedule. Fluid-applied membranes conform to complex surfaces, while sheets offer consistent thickness and pre-tested performance.

Fluid-Applied Membrane Advantages

  • Excellent for irregular or complex geometries
  • Monolithic and seamless once cured
  • Faster application on large vertical areas
  • Easy to repair and detail in field

Products include polyurethane, asphalt-emulsion, and rubberized asphalt types. Verify wet mil thickness and curing time based on temperature and humidity.

Sheet Membrane Advantages

  • Pre-measured thickness (typically 40–60 mil)
  • Controlled quality—factory-produced sheets
  • Less sensitive to weather conditions at installation
  • Integral drainage and protection layers available

Use primer for better adhesion. Ensure seams are fully lapped and rolled. Watch for fishmouths or wrinkles during installation.

Drainage Boards and Protection Mats

Always protect membranes from backfill damage using dimple drainage boards or geo-textile mats. These also help relieve hydrostatic pressure and direct water to footing drains. Some sheet systems come with integrated drainage layers bonded to the waterproofing membrane.

Below-Slab and Blindside Applications

For mat slabs or under-slab installations, pre-applied sheet membranes are typically used. Blindside systems against soil retention walls require nailed or bonded membranes installed before formwork. Overlap and adhesion are critical in these pre-applied cases as visual inspection may be impossible later.

Code Compliance and Testing

Confirm compliance with ASTM C836 (liquid) or ASTM D1970 (sheet). For high-performance sites, conduct adhesion and flood tests before covering. Detail terminations at penetrations, tie-ins to above-grade WRBs, and foundation wall transitions. Monitor water table depth for membrane selection—positive-side waterproofing is preferred where feasible.

Residential

26 Jun 2025

This article covers advanced methods, materials, and considerations for metal cladding underlayment and thermal break layers in modern construction.

Disclosure: As an Amazon Associate, EnvelopeIQ earns from qualifying purchases.

Expanded Guidance

This article on Metal Cladding Underlayment and Thermal Break Layers includes key strategies for envelope continuity, product selection, code compliance, and typical failures to avoid. Systems are described with links to example products and performance tips based on field conditions.

🔍 Recommended Products

Best Practice Tips

  • Ensure compatibility with adjacent layers and substrates
  • Sequence flashing and weather barriers shingle-style
  • Use mockups and field adhesion tests before bulk installation
  • Coordinate across trades to maintain control layer continuity

Combining WRBs and Thermal Breaks

Metal cladding systems often combine water-resistive barriers with thermal break layers like mineral wool or foam boards. Use z-girt spacers thermally isolated from structural framing. When using underlayment or synthetic WRBs, verify their maximum service temperature against dark metal solar exposure.

Role of Underlayment in Metal Cladding Systems

Underlayment layers beneath metal panels protect against moisture intrusion and control air and vapor movement. In rain-exposed assemblies, use a water-resistive barrier (WRB) that also acts as an air barrier. Options include mechanically fastened building wraps, peel-and-stick membranes, or fluid-applied WRBs depending on exposure and structural substrate.

Thermal Bridging in Furring and Framing

Metal clips and furring can become significant thermal bridges in continuous insulation assemblies. Interrupt the thermal path using plastic thermal spacers, fiberglass brackets, or thermally broken z-girts. Some systems use offset clips with stand-off screws to reduce direct conductive contact between cladding and structure.

Common Thermal Break Systems

  • Thermally Broken Z-Girts: Continuous insulation support with polymer inserts
  • Clip-and-Rail Systems: Support brackets with non-metallic isolators for ventilation
  • Horizontal Hat Channels with Spacer Tape: Cost-effective option when used over insulation

Fire Resistance and Moisture Drainage

Ensure WRBs and thermal break systems comply with NFPA 285 and allow vertical drainage in back-ventilated façades. Drainage mats or grooved insulation can facilitate air movement and drying behind panels. Avoid using closed-cell foams without venting behind dark metal claddings which reach high surface temperatures.

Installation Tips and Long-Term Durability

Always follow the metal panel manufacturer’s detailing requirements for underlayment compatibility and fastening patterns. Use stainless steel fasteners and check that furring is aligned and level. Periodic inspection is necessary to identify dislodged panels, sealant breakdown, or underlayment exposure over time.

Residential

26 Jun 2025

This article covers advanced methods, materials, and considerations for masonry weep systems: best practices and details in modern construction.

Disclosure: As an Amazon Associate, EnvelopeIQ earns from qualifying purchases.

Expanded Guidance

This article on Masonry Weep Systems: Best Practices and Details includes key strategies for envelope continuity, product selection, code compliance, and typical failures to avoid. Systems are described with links to example products and performance tips based on field conditions.

🔍 Recommended Products

Best Practice Tips

  • Ensure compatibility with adjacent layers and substrates
  • Sequence flashing and weather barriers shingle-style
  • Use mockups and field adhesion tests before bulk installation
  • Coordinate across trades to maintain control layer continuity

Weep Hole Placement and Flashing

Install weep holes at the base course of masonry veneer every 24 to 32 inches. Use rope wicks or plastic weep inserts, and ensure flashing extends beyond the face of the wall. End dams are critical at flashing terminations to redirect water outward rather than into adjacent assemblies.

Design Principles Behind Weep Systems

Masonry veneer walls rely on a drainage cavity and properly detailed weeps to evacuate water that enters through mortar joints or porous brick. A typical weep system includes a through-wall flashing, drainage mesh, and weep vents located just above the flashing level. This setup prevents moisture accumulation and protects the structural wall.

Through-Wall Flashing Materials

Use non-corrosive, durable materials such as stainless steel, copper-laminated flashing, or rubberized asphalt membranes with termination bars. Flashing must extend fully through the veneer and bend downward to shed water. End dams and lap joints must be sealed to prevent lateral water intrusion along the wall plane.

Types of Weep Systems

  • Rope or wick weeps: Twisted cotton or synthetic cords embedded in joints
  • Veneer vents: Plastic louvered inserts placed in head joints
  • Open head joints: Simple, unobstructed openings every 24-32″
  • Integrated drip edges: Flashing with molded weep slots

In cold climates, avoid steel or unvented weeps that can freeze shut. Use insect screens in regions prone to pests or termites.

Drainage Cavity and Mortar Management

The air space between veneer and backup should be a minimum of 1″, preferably 2″ for optimal drainage. Install mesh mortar nets or droppings control mats at base to prevent blockage. Clean cavities before closing veneer courses and inspect during installation for mortar bridging or collapsed insulation.

Inspection and Maintenance Practices

Inspect weeps visually at grade level to ensure open flow paths. Poor workmanship can often be diagnosed by uneven staining, efflorescence, or water damage near base-of-wall joints. Maintenance includes resealing flashing terminations and replacing clogged weep vents over time.

Residential

26 Jun 2025

This article covers advanced methods, materials, and considerations for eifs drainage systems and wrb compatibility in modern construction.

Disclosure: As an Amazon Associate, EnvelopeIQ earns from qualifying purchases.

Expanded Guidance

This article on EIFS Drainage Systems and WRB Compatibility includes key strategies for envelope continuity, product selection, code compliance, and typical failures to avoid. Systems are described with links to example products and performance tips based on field conditions.

🔍 Recommended Products

Best Practice Tips

  • Ensure compatibility with adjacent layers and substrates
  • Sequence flashing and weather barriers shingle-style
  • Use mockups and field adhesion tests before bulk installation
  • Coordinate across trades to maintain control layer continuity

Drainage Mat Layers and Detailing

EIFS with drainage typically includes a grooved or mesh drainage mat behind the foam insulation. This ensures incidental moisture that bypasses the finish coat drains away quickly. Use proprietary WRBs approved for EIFS and verify with NFPA 285 assembly compliance when required. Monitor termination details at weeps and base of wall transitions.

EIFS System Components and Drainage Variants

Modern EIFS systems consist of five key components: a water-resistive barrier (WRB), adhesive or mechanical attachment, foam insulation, base coat with embedded mesh, and a finish coat. Drainage EIFS incorporates a drainage plane between the foam and WRB, typically using vertical channels, grooved insulation, or drainage mats.

Manufacturers such as Dryvit, Sto, and Parex offer proprietary systems tested to meet ASTM E2273 (water drainage performance). Selecting the appropriate drainage configuration depends on local climate, exposure, and wall height.

Compatibility Testing and Substrate Conditions

Not all WRBs are approved for use behind EIFS. Liquid-applied WRBs are generally preferred for continuity and ease of sealing around fasteners and penetrations. Sheet membranes can be used if manufacturer-approved and properly lapped at transitions. Always conduct adhesion testing to confirm compatibility with adhesives or base coats.

Substrate preparation is critical. DensGlass, cement board, and CMU must be clean, dry, and primed where required. Avoid installation over OSB unless specifically permitted in the evaluated system report.

Drainage Detailing and Weep Integration

The drainage path must exit at the base of the wall or over horizontal terminations such as flashing or window heads. Use perforated base trims or proprietary weep tracks. Do not seal horizontal joints unless required to block pests or wind-driven rain. Monitor cavity ventilation as excessive openings can reduce thermal performance.

Fire, Moisture, and Code Compliance

EIFS systems must comply with NFPA 285 in multi-story applications where foam plastic is present. Assembly selection should reference ICC-ES ESR reports and include details for fire-stopping, deflection gaps, and joint reinforcement. Moisture intrusion behind poorly installed EIFS has historically caused significant damage—ensure 100% coverage at joints and terminations.

Maintenance and Inspection Guidelines

Regular inspection of sealant joints, finish integrity, and base-of-wall drainage is critical to long-term EIFS performance. Many manufacturers recommend resealing control joints every 5–7 years. Look for signs of discoloration, cracking, or delamination as indicators of failure behind the surface layer.